Screw air compressor installation standards and requirements?
A. Installation environment layout requirements
In order to meet the needs of development, the equipment room should have room for expansion in the position of the general plan.
2. The air compressor directly inhales from the atmosphere. In order to reduce the possibility of wear, corrosion and explosion of the unit, the machine room must have a certain distance from the place where explosive, corrosive, toxic gas, dust and other harmful substances are emitted. The heat dissipation of the compressor is large, especially in summer, the temperature inside the machine is very high, so the orientation of the machine room should be such that the machine has good ventilation and minimize sun exposure.
3. Although the compressor has a box body, it is strictly forbidden to rain, so the compressor should not be installed in the open air.
4. The compressor room is an independent building.
5. The compressor room must be equipped with a fixed fire extinguishing carbon dioxide fire extinguishing device whose manual switch must be placed outside the danger zone. And can be reached at any time. Fire-fighting equipment Carbon dioxide fire extinguishers or powder fire extinguishers should be placed near the protected target, but should be outside the danger zone.