How to prevent air compressor temperature from being too hot in hot summer
On the occasion of the hot summer, due to the high temperature of the air compressor, the failure often occurs, and the users of various enterprises are eagerly awaiting each other, and each unexpectedly responds to the sudden situation of the air compressor!
1. Environmental ventilation and heat dissipation are not good
There are three main situations in which the surrounding environment of the air compressor affects heat dissipation: one is too close to the wall obstacles; the other is that there are other heat sources near the air compressor, and the third is that the front door and the side door of the air compressor are open during operation, and the fan cannot form a strong air flow.
2, the radiator is blocked
When there is a lot of dust around the air compressor, the long-term operation will cause a layer of dust or sludge to adhere to the surface of the radiator, and the internal copper tube is also likely to be blocked due to the accumulation of grease, thus affecting the heat dissipation effect.
3, the oil filter is too dirty
The air compressor has three side-by-side oil filters. When it is too dirty, the resistance oil cannot enter the compressor at the normal flow rate, and the compressor will heat up rapidly due to insufficient cooling oil. When the inlet and outlet oil pressure difference exceeds 0.18MPa, the filter element needs to be replaced.
4, the cooling oil level is too low
When the cold machine is inspected, the oil level should be replenished immediately below the lower end of the inspection tube.