How to relieve high temperature shutdown ?
Pull the air open to the open position, start the air compressor, the unit start display is loaded, the actual intake valve is closed (unloading operation), after 2 minutes of no load, open to the closed position, the air compressor starts Load and run, close the switch for 5 seconds, pull down the switch again, and let the air compressor unload and run. Close it again after 2 minutes, then repeat the operation 2-3 times, then close the switch and run for 5-10 minutes to observe the exhaust. Temperature rise rate and temperature rise range, if the exhaust gas temperature is basically stable between 82-94 °C, indicating that the air compressor has reached normal operating conditions, can operate normally; according to the temperature condition, open and close the exhaust port sliding door; When the exhaust gas temperature is above 92 °C, adjust the sliding door opening according to the ambient temperature.) When the ambient temperature is above 5 degrees, it can be started according to the normal starting procedure;