How is the air compressor automatically starting and stopping?
In the process of using the air compressor, some troubles will inevitably occur. For example, the air compressor often encounters the phenomenon of automatic start and stop during work. Then, how does the air compressor automatically start and stop? How to solve it? Next, the air compressor manufacturer technicians will answer you:
1. Electrical parts:
The air compressor suddenly stops during the operation. It should first check whether there is a fault prompt. If there is a fault prompt, check it. If it is not, continue to check it out. When the air compressor is in use, there is a phase failure prompt to check whether the air opener and the contactor are normal. If there is a focal spot due to electric shock, it is recommended to replace the new one.
2, the controller:
The controller has a shutdown delay during use, which means that the main controller is broken and needs to be replaced. Because no one presses the close switch during the work, the machine cannot display a stop delay. Remember that there is no fault at this time.
3, the fuse:
The air compressor is normal at the time of starting up. During the star-delta conversion process or when the loading operation is stopped, the fuse should be checked first and the fuse is blown. Check the motor and the machine head for any jamming. At this point, it should be an overcurrent shutdown. It is recommended to check the motor and the machine head.
4. Intake valve failure:
The valve cannot be closed during unloading and is still inhaling, resulting in a high pressure shutdown.
5, oil core blockage:
The use of lubricating oil is of poor quality and the use of lubricating oil for a prolonged period of time may result in oil blockage. The internal pressure of the machine is high, and the oil is stopped after the machine is at a high temperature. Under normal circumstances, the pressure difference between the inside and outside of the oil core is not more than 1 kg.
6, emergency stop switch failure:
If the emergency stop switch fails, the machine will also stop, and if the pressure or temperature sensor is broken, the machine will stop.
The above is about the automatic start and stop of the air compressor is introduced to this, permanent magnet inverter air compressor is now hot products in the air compressor market, is the focus of the majority of manufacturers and users. With the increasing awareness of energy conservation among users, the development potential of permanent magnet variable frequency air compressors is huge.