Jul 30, 2019 Leave a message

Effective Way To Improve The Service Life Of Air Compressor

Effective way to improve the service life of air compressor

Air compressor valve block valve use

The valve plate is used on both sides, and the force on both sides of the valve plate is evenly increased, which improves the life of the valve plate; the replacement of the valve base after wear is relatively wasteful, and we raise the spring by 1 to 2 mm to overcome the phenomenon of poor sealing of the valve block caused by wear and tear. The life of the valve is more than doubled in five or six years.


Improved cooling system

1) Cooling method

The water cooling system before the improvement is shown in Figure 1. The cooling water* enters the intercooler, the outlet water temperature has risen, and then the three channels enter the first and second stage cylinders and the oil cooler respectively, when the ambient temperature is low in winter. This cooling method has little effect on the normal operation of the air compressor. In summer, due to the high ambient temperature itself, the inlet temperature of the air compressor is around 30cE, and the outlet temperature reaches about 45°C, which exceeds the inlet temperature of the air compressor. ≤ 20 ° C, drainage temperature ≤ 40 ° C requirements, resulting in air compressor overheating operation.


Send Inquiry

whatsapp

skype

E-mail

Inquiry