After Reading This Air Compressor Fault Summary, It Is Half A Compressor Repair Expert.

After reading this air compressor fault summary, it is half a compressor repair expert.


We often encounter such small problems when using air compressors. Some minor problems may be particularly difficult for people who don't know how to do it, but for those who are familiar with the industry, it is pediatrics.


1. The head outlet temperature or exhaust temperature is high


Excessive temperature rise is a common fault in the operation of screw air compressors. Screw air compressors are often operated at high temperatures, which will seriously affect the displacement and service life of the machine. When the temperature rise is too high, a high temperature shutdown shutdown will occur. The reasons are:


1. The temperature sensor is faulty. If the temperature sensor fails, it will cause the PLC to falsely report that the temperature is too high, causing the machine to stop.


2. Environmental temperature factors. The screw air compressor head temperature is generally set at about 110 ° C, and the head outlet temperature is equal to the ambient temperature plus 60 ° C. The ventilation environment is poor, and most of the temperatures are too high.


3. The temperature control valve is faulty. When the compressor is cold-started, the oil can be directly sprayed into the main head by the oil bypassing the cooler to accelerate the rise of the oil temperature and prevent condensation in the compressor. After the compressor is in normal operation, it can be cooled according to the oil temperature. The ratio of the amount of oil in the pump and the circuit to control the injection temperature. If the temperature control valve is damaged or the action is not sensitive, a large amount of high temperature oil will be directly circulated into the main head without passing through the cooler, resulting in high temperature of the host.


4. The oil filter is faulty. The oil filter is used to filter dust and impurities in the oil circuit. It is easy to block after a period of use, and the oil return is not smooth after the blockage, causing the host temperature to be high (often occurring at the loading moment).


5. The oil shutoff valve is faulty. The oil shut-off valve controls the reciprocating motion of the oil through the air pressure of the gas storage tank. If the oil circuit is not smooth due to the failure, the oil temperature is high; the debris blocks the oil circuit or controls the gas circuit, causing the oil shut-off valve to close without spraying oil. It will cause the host head to have high temperature due to lack of oil or poor heat dissipation.


6. The amount of lubricating oil is insufficient, and the oil cooler is dirty and clogged, which will cause the temperature to be too high.


7. The cooling fan fails, the air cooler is blocked, and the exhaust resistance is too large, causing a high temperature due to poor heat dissipation. The external dust and internal oil of the cooler should be cleaned.


8. The unloading pressure setting is too low, resulting in excessive oil resistance during the unloading cycle of the air compressor. If the flow rate is too slow, the heat is not dissipated in time, causing high temperature shutdown and shutdown. Therefore, the unloading pressure should be set reasonably.