Winter air compressor Power Notes :
Before starting the air compressor, ensure that the air pressure of the air compressor is not lower than 5 °C. If the temperature is too low, use a heating device to heat the oil separator and the main part.
Check that the oil level is in the normal position and check that all condensate drains are closed. For water-cooled units, check that the cooling water drain is closed.
The hand-cranked main coupling is flexible to rotate. For the unit that is difficult to drive, please do not blindly start the machine. Check whether the main unit is faulty, whether the lubricating oil is thick or not, and remove the fault before starting.
The new oil filter should be replaced before the initial start of the air compressor with long downtime to reduce the resistance caused by oil viscosity and insufficient oil supply.
It is best to jog the unit once the power is turned on for the first time. After the power is turned on, the current and oil temperature should be checked. If there is a sudden change in temperature, stop it immediately. For the unit with heat recovery, the oil bypass valve on the heat recovery system should be turned off before the unit is turned on, and then the heat recovery system is slowly turned on after the normal opening temperature of the unit rises to the normal range.
For units with sudden temperature changes or high temperature trips, remember not to turn on the power repeatedly. The intake valve should be opened, and the proper amount of lubricating oil should be added to the main unit.