Sep 03, 2018 Leave a message

Safe operation of air compressor

Safe operation of air compressor :


1.Reasonable use of labor protection supplies, vouchers to operate equipment


2.We will stick to our posts and strictly implement the shift handover system, the post responsibility system and the registration system for entry and exit of foreign personnel.

  Flammable and explosive articles are not allowed in the machine room.


3.Check the protective equipment and safety accessories in good condition before driving; otherwise, do not drive


4.Check whether the lubricating oil level is up to standard


5.The pressure gauge should be checked regularly, the external inspection of gas storage tank and conduit joint should be done every year, the internal inspection and hydraulic strength test should be done every three years, and detailed records should be made, indicating the working pressure on the gas storage tank and the date of the next test


6.The safety valve is automatically started once a month and calibrated every six months with lead seals


7.In the inspection and repair, should be careful to avoid wood, iron, cloth, such as falling into the cylinder, gas storage tanks and catheters


8.The cleaned parts must run without load for 10 minutes before being put into normal operation


9.No repair work shall be carried out while the machine is in operation or under pressure


10.In case of any abnormal sound, smell, vibration or malfunction during operation, the machine should be stopped immediately before use


11.Before starting, open the cooling water valve and then the motor.When there is no cooling water or water cut off, the operation shall be stopped


12.Always pay attention to the change of pressure pointer and forbid exceeding the specified pressure


13.When the work is completed, the residual gas in the air storage pipe is released.Cooling water should be discharged in winter


Send Inquiry

whatsapp

skype

E-mail