Analysis of fault maintenance of air compressor intake valve
In July of this year, during the operation of an air compressor unit, it was difficult to start loading and loading. It can be judged from the loading sound that there was a problem during the loading process. However, due to the urgent production task of Party A, the gas source could not be interrupted. The maintenance personnel only replaced the loading solenoid valve without affecting the production gas.
However, in less than two days, the maintenance department received an emergency call. The air compressor could not be loaded with air. The unit was only empty and had no compressed air. In response to this phenomenon, let us first understand the working principle of the air compressor loading valve:
When the air compressor intake valve is started, it is closed, the motor drives the main engine to be unloaded, and when it needs to be loaded, the intake valve opens. Generally, a gas pipe larger than 5 mm is taken out from the top cover of the oil separator, and the intake valve is controlled by the switch of the electromagnetic valve (the solenoid valve is a normally open electromagnetic valve), that is, when the electromagnetic valve is energized, no compressed air enters the intake valve, and The air valve is automatically sucked open, the intake valve is loaded, and the air compressor starts to pump. When the solenoid valve is de-energized, the compressed air enters the intake valve, the air pressure pushes up the piston, the intake valve closes, and the venting vent valve opens.
The air pressure is divided into two ways, all the way into the air venting valve exhaust, all the way into the compressor. The bleed valve has a joint that adjusts the size of the exhaust to control the pressure in the tank of the oil separator. The pressure can generally be adjusted to 3 kg, the pressure in the clockwise direction is increased, the pressure in the counterclockwise direction is lowered, and the nut is tightened after adjustment.
Gas filling method of loading valve
When the user's air consumption is less than the rated exhaust capacity of the unit, the pressure in the user pipe network system will rise. When the pressure rises to the unloading pressure set value, the solenoid valve loses power and cuts off the internal combination valve of the intake controller. Control gas source. The piston is closed by the spring force, and the vent valve is opened, and the compressed air in the oil separator is returned to the intake port, and the pressure drops to a certain value.
At this point, the minimum pressure valve is closed, separating the user pipe network from the unit, and the unit is in no-load operation. As the pressure of the user pipe network gradually drops to the set value of the loading pressure, the solenoid valve is energized, and the control air source that enters the internal combination valve of the intake controller is turned on, and the piston is opened under the action of the pressure against the spring force, and at the same time venting The valve is closed and the unit resumes loading and running.
By knowing the compressor operation process, we know that the loading valve is a frequent loading and unloading component. For the fixed-frequency unit, the air pressure of the air compressor is controlled by the loading and unloading pressure. The unit does not need to be unloaded and unloaded. Both of them need to be unloaded and replaced to realize this function. The loading and unloading valve needs to attract our attention.
Intake valve does not load
the reason:
1, the solenoid valve is not powered
2, the solenoid valve is damaged
3. Impurities in the solenoid valve cause the malfunction of the exhaust port
4. The deterioration of the lubricating oil causes the friction between the piston seal ring and the cylinder of the intake valve to increase and cannot be reset.
5, the tolerance valve controls the intake valve to close
Remedy:
1. Check the circuit and restore the solenoid valve to normal.
2. Replace the solenoid valve coil or the entire solenoid valve body.
3. Disassemble the solenoid valve to remove internal impurities.
4. Disassemble the intake valve to remove the oil stain inside the intake valve, remove the grease on the inner wall of the intake valve cylinder, and replace the new stable quality lubricant.
5. Adjust the tolerance valve (module) of the intake valve.
Intake valve is not unloaded
the reason:
1, the solenoid valve is not powered off
2, the solenoid valve is damaged
3. The small hole in the solenoid valve is blocked
4, the intake valve is blocked in the intake hole
5, the discharge speed is too fast
Remedy:
1. Check the circuit and restore the solenoid valve to normal.
2. Replace the solenoid valve coil or the entire solenoid valve body.
3. Disassemble the solenoid valve to remove internal impurities.
4. Disassemble the intake valve to remove impurities in the intercepting hole.
5. Adjust the discharge speed, add the atmospheric tube diameter or add an elbow.
Intake valve fuel injection
the reason:
1. Oil and gas separator is defective
2, the oil return check valve is blocked
3. The air filter has poor filtering effect, and the sealing surface of the inlet valve spool adheres to impurities, resulting in poor sealing.
4, the working environment of the air compressor is bad, the intake valve piston and the spring seat cooperate with the wear
Remedy:
1. Check the oil separator and replace it with a new oil core.
2. Remove the oil return check valve to remove the internal impurities of the check valve.
3. Check the air filter and replace with the new air filter. The intake valve pipe is cleaned.
4. Replace the new intake valve, shorten the maintenance cycle of the air compressor and recommend that the air compressor user improve the working environment of the air compressor.
maintenance
In order to better operate the air compressor unit, it is necessary to strengthen the maintenance of the loading and unloading valve. The maintenance contents are as follows:
1. The operating personnel should pay attention to observe the loading pressure of the unit daily;
2. Determine the presence or absence of mechanical accent during the unloading process by loading and unloading the sound;
3. According to the maintenance plan, every 10,000 hours of operation, carry out a formal inspection to meet the purpose of use, otherwise replace it in time.