Xiamen HighQ Compressor Co., Ltd

High quality product, professional service, being the core supplier in compressor industry

Home > News > Content
Screw Air Compressor Not Maintenance On Time Against
- Nov 19, 2016 -

1, screw air compressor air filter periodically blowing dust, replaced cause: air filter block, intake decreased, emissions are reduced. Do not change regularly would have negative pressure increases wear, contaminants from entering the machine, plug oil filter, oil separation core, cooling and lubrication oil, hosts wear.
2, screw air compressor oil return pipe joints are not clean: jams, separated a few oil with air into the pipe, causing oil consumption oil shortage.
3, screw air compressor oil filter is not replaced on a regular basis: with the increasing pressure before and after, oil reduction, exhaust temperature of screw air compressor mainframe outages, such as before and after difference is too large to penetrate, contaminants from entering the machine, plug oil core hosts wear.
4, screw air compressor motor bearings are not regular butter: bearing wear until the main motor burned out.
5, screw air compressor oil separation axis does not change: with the increasing pressure before and after, main motor current increases, emissions are reduced. As great as the pressure difference before and after the breakdown, cooling and lubrication oil with air into the pipe until the finish, hosts the exhaust temperature is down.